Product compatibility
Fits both DL-6 and VanDOOR AluLIFT.
Reference verified on the VanDOOR ranges below. Any out-of-scope install requires engineering validation.
Compatible range

Lifecycle
Annual
Cadence pulled from manufacturer manuals. Preventive maintenance recommended to preserve torque, sealing and operator safety.
Technical specifications
2 documented specifications
Headline spec
Batterie
Additional data
Product compatibility
Reference verified on the VanDOOR ranges below. Any out-of-scope install requires engineering validation.
Compatible range
Related documentation
Manuals and datasheets referenced for this part.
Order alongside
Ersatzteil-FAQ
Up to 12 transmitters can be paired per system, identical on DL-6 and AluLIFT. Procedure: cut power, reconnect the battery cable, within 5 seconds press buttons 1 and 2 simultaneously to enter learning mode, then press any button on each remote to be paired. Any remote not included in this session is wiped. With no action for 5 s, learning mode exits automatically.
SRCFR---Manuel-utilisateur-DL-6.mdl.336-338
The FOB remote runs on an A23 dry-cell — 12 V, replace if range drops or the remote becomes intermittent. Replacement is scheduled at the annual service. Universal reference available in retail. No specific tooling required.
SRCFR---Manuel-utilisateur-DL-6.mdl.336-340 + maintenance l.678-679
Pairing procedure: (1) unplug both the battery cable AND the motor profile cable; (2) reconnect only the battery cable — within 5 seconds, press buttons 1 and 2 simultaneously (open + close) → the system clears memory and enters learning mode (relay triggered); (3) within 5 s, press any button on each remote to pair (max 12); (4) wait 5 s with no action to exit learning mode; (5) once LED 1 is steady green, reconnect the profile cable. Any remote not included in this session is wiped.
SRCManuel-instruction-utilisation.mdl.366-402
Praxiswissen
Kritische Verfahren, um einsatzbereit zu bleiben — Notentriegelung und Qualifikation des Installateurs.
External release procedure: (1) insert the DoorLIFT key into the lock cylinder at the centre of the intermediate or top panel, outside face; (2) turn the key 90° clockwise and firmly pull the lock and cable out of the cylinder — the system disengages; (3) reinsert the cable and cylinder into the door lock housing, then operate the door by hand. On the AluLIFT, an internal release is available: pull the red sleeve marked 'EMERGENCY DOOR RELEASE' to disengage the motor lever from inside the box.
SRCFR---Manuel-utilisateur-DL-6.mdl.617-632 + utilisation l.420-449
VanDOOR does not perform installation itself. AluLIFT integration must be carried out exclusively by qualified, trained bodybuilders or integrators, in accordance with Machinery Directive 2006/42/EC and best practice. The integrator guarantees regulatory compliance of the final assembly, verifies correct operation, commissions the system, and supplies the end user with the manual and CE Declaration of Conformity for the integrated equipment.
SRCManuel-instruction-installation.mdl.45-72