Häufige Fragen zu diesem Ersatzteil

  • The AluLIFT offers 5 push-button references: DL-8000810 (up/down, stainless cover, rear frame); DL-8000811 (optional cab button, open-only, wire 2); DL-8000814 (stainless NO pair, up/down, rear frame); DL-8000815 (NO held-pressure, two-hand dead-man control); DL-8000816 (NO open from inside the box). All five connect via the 8-wire auxiliary harness on the control box. The DL-6 offers a single standard button option.

    SRCManuel-instruction-utilisation.mdl.310-340

  • Up to 12 transmitters can be paired per system, identical on DL-6 and AluLIFT. Procedure: cut power, reconnect the battery cable, within 5 seconds press buttons 1 and 2 simultaneously to enter learning mode, then press any button on each remote to be paired. Any remote not included in this session is wiped. With no action for 5 s, learning mode exits automatically.

    SRCFR---Manuel-utilisateur-DL-6.mdl.336-338

Documentary sourceManual Manuel-instruction-utilisationLines 310DL-8000810

Praxiswissen

Zwei Punkte, die man vor allem anderen kennen sollte

Kritische Verfahren, um einsatzbereit zu bleiben — Notentriegelung und Qualifikation des Installateurs.

  • External release procedure: (1) insert the DoorLIFT key into the lock cylinder at the centre of the intermediate or top panel, outside face; (2) turn the key 90° clockwise and firmly pull the lock and cable out of the cylinder — the system disengages; (3) reinsert the cable and cylinder into the door lock housing, then operate the door by hand. On the AluLIFT, an internal release is available: pull the red sleeve marked 'EMERGENCY DOOR RELEASE' to disengage the motor lever from inside the box.

    SRCFR---Manuel-utilisateur-DL-6.mdl.617-632 + utilisation l.420-449

  • VanDOOR does not perform installation itself. AluLIFT integration must be carried out exclusively by qualified, trained bodybuilders or integrators, in accordance with Machinery Directive 2006/42/EC and best practice. The integrator guarantees regulatory compliance of the final assembly, verifies correct operation, commissions the system, and supplies the end user with the manual and CE Declaration of Conformity for the integrated equipment.

    SRCManuel-instruction-installation.mdl.45-72